Amuma Plus Low frequency hybrid Inverter 5 KVA / 48V ( GAPS-5048)
Grovolt Amuma Plus Low frequency hybrid Inverter 5 KVA
Features:
- Support Lithium battery with auto wake up ,
- Compatible with multiple lithium battery’s communication
- Support RS232 for WIFI (optional)
- Pure sine ware output Powerful Charge Rate.
- Hybrid with optional MPPT / PWM solar charge controller
- DC Start
- Automatic Self-Diagnostic Function
- High Efficiency Design & ”Power Saving Mode” to Conserve Energy
- Auto restart when Ac in recovering
- Smart battery charger design for optimized battery performance
- Selectable charging current based on applications AC input/DC input/Solar input
- optional priority Built-in Transformer Wall-Mounted
Amuma Plus Low frequency hybrid Inverter 5 KVA / 48V ( GAPS-5048)
Grovolt Amuma Plus Low frequency hybrid Inverter 5 KVA
Features:
- Support Lithium battery with auto wake up ,
- Compatible with multiple lithium battery’s communication
- Support RS232 for WIFI (optional)
- Pure sine ware output Powerful Charge Rate.
- Hybrid with optional MPPT / PWM solar charge controller
- DC Start
- Automatic Self-Diagnostic Function
- High Efficiency Design & ”Power Saving Mode” to Conserve Energy
- Auto restart when Ac in recovering
- Smart battery charger design for optimized battery performance
- Selectable charging current based on applications AC input/DC input/Solar input
- optional priority Built-in Transformer Wall-Mounted
Capacity(VA) | Amuma Plus5000VA |
Input Voltage(DC) | 48V |
Nominal Voltage | 220VAC |
Voltage Range | 154-265VAC (AC Model);185-264VAC±3V(UPS Model) |
Frequency | 50-60HZ Auto sensing |
Power Factor | 0٫8 |
Rated Power | 4000W |
Voltage | 220VAC |
Frequency | 50/60HZ |
Waveform | Pure Sine Wave |
Transfer Time (AC to DC) | <8ms |
Transfer Time (DC to AC) | <8ms |
Output Voltage Regulation | 土10% |
Bypass Mode | Yes |
Saver Mode | Yes |
Efficiency | >98% |
Input Protection | Circuit Breaker |
Output Protection | Circuit Breaker |
Battery Type | AGM-Deep Cycle ,Gel/Turbular/Lithium Battery |
Charging Current | 30A |
Low Level disconnect (Selectable) | 40V or 42V |
PWM(Optional) controller Voltage | 30VDC-105VDC |
MPPT(Optional) controller Voltage | 15VDC-150VDC for 12V ; 30-150VDC for 24V; 60-150V for 48V |
Maximum PV array power | 3200W |
Maximum PV array open circuit voltage | MPPT:150VDC |
Maximum solar charge current | 60A |
Protections | Over load, over temp, over charging, battery low, battery reverse connect, high AC voltage etc. |
LCD indicator status | AC input voltage, AC input frequency, PV voltage, PV current , Output Voltage, Output Frequency, Battery voltage, Load current etc. |
LED indicator status | AC Line In:Green/Inverter:Green/Charging :Yellow/Alarm :Red |
LOW battery alarm | Audible alarm-5 seconds beeping |
Overload alarm | Audible alarm- continuous beeping |
Fault | Audible alarm- continuous beeping |
Temperature | 0-40℃ |
Humidity | —10℃~90℃ Non condensing |
Accoustic Noise(db) | >55dB |
Size L*W*H(mm) | 465*310*135MM |
carton size L*W*H(mm) | 555*375*198MM |
Weight (kg) | 23٫33 |