Online UPS TIGER TG-3KVA / 2400W ( TG-1KVA )
Tiger Online UPS TIGER TG-3KVA
Features : High Frequency Smart Online UPS
0msTransfer Time (AC to DC)
Single Pase
Capacity from 1KVA to 10KVA
LED Display
Smart RS-232
Frequency Range 47Hz-53Hz or 57Hz – 63Hz
Online UPS TIGER TG-3KVA / 2400W ( TG-1KVA )
Tiger Online UPS TIGER TG-3KVA
Features : High Frequency Smart Online UPS
0msTransfer Time (AC to DC)
Single Pase
Capacity from 1KVA to 10KVA
LED Display
Smart RS-232
Frequency Range 47Hz-53Hz or 57Hz – 63Hz
| #IodeI | TG-3KVA |
| Phase | Single-phase |
| Capacity | 3000VA/2400W |
| Input | |
| Voltage Range | 110-300VAC in 50% load 16&300VAC in 100% load |
| Input Return Voltage | 110-300V |
| Frequency Range | 40Hz -70Hz |
| Power Factor | |
| Output | |
| Output Voltage | 220VAC1 1%é”208/220/230/240the panel is adjustable EO |
| Voltage nnge (Batt. Mode) | z1% |
| Frequency Range (Sync Calibration Range) | 47Hz-53Hz or 57Hz – 63Hz |
| Fequency Range (Bat. Mode) | 50 Hz (60Hz optional z 0.25 Hz |
| Harmonic Distortion | ?3% THD(linear load) ?6% THD (Nonlinear load) |
| Transfer Time (AC to DC) | 0ms |
| Transfer Time (inverter to bypass) | 4 ms(standard) |
| Waveform | Pue sine wave |
| Battery | |
| Standard Model Battery Type | 12V/7AH |
| Standard Model Battery Quantity | 8 |
| Standard Model Charging CuiTent | 1.0A(Max) |
| Standard Model Charging Voltage | 110VDC 1 1% |
| Long Run Model Battery Type | Depends on the buyer |
| Long Run Model Bateiy Quantity | 8 |
| Long Run ModelCharging CuiTent | 4A or 8A(standard is 4A) |
| Long Run ModelCharging Voltage | 110VDC z 1% |
| Protection against | |
| Full time lightning pmtection, noise and surge protection; | |
| Output short circuit protection and ovei1oad protection | |
| Appearance | |
| LCD Display | Using LCD display, the status parameters at a glance; Load level, battery capacity, AC Mode, batey mode, bypass mode, fault indication |
| Alarm | |
| Battery Mode | Alam beeps every four seconds |
| Low Bateiy | Alam beeps every second |
| Ovefload | Alam beeps every second |
| Fault | Alarm beeps continuously |
| interlace | |
| SmaRRS232ineñacQUSBi:eñacetoxmmuNwtevithengineer) | |
| Environment | |
| Temperature And Humidity | Humidity 20-90%, temperatue 0-40°C (non-condensing) |
| Noise(dB) | < 50dBA at one meter distance |
| Control Management | |
| Smart RS-232 | Support Windows‹B 2000/2003/XP/\/ista/2008,Windows 7/8,Linux,Unix |
| Optional SNMP | Power Management supports SNMP management and netwoil‹ management |
| External Dimension | |
| Standard Model Dimension(mm) | 450’192”335 |
| Standard ModeIWeight(KGS) | N.W:27.7 |
| Long Run Model Dimension(mm) | 450*192*335 |
| Long Run ModeIWeight(KGS) | N.W:13 |
| Warranty | |
| 15months warranty on Spare Parts / 3 Months On batteries | |
| Certification | |
| IS09001/IS014001/CE Certification | |